Enables DMMs and other testers to measure electrical current.

Model # 
Description

Image

Range

Accuracy

Output

General Specifications

Compatible Units

A250 (AC Amp Current Probe Adapter)

 

 


Data Sheet

AC Amps: 0 to 400A

DC Amps: N/A

0 - 40A = ± 1% of reading

0 - 400A = ± 1.5% of reading

1mA per 1A

Maximum Conductor Size: 1.34” (34mm)

Lead Length: 48” (1.2m)

Output Connection Type: Dual banana plug

TPI 153, 163, 183, 183A, and 440 to obtain .01 A resolution

 

A251 (AC Amp Current Probe Adapter)

AC Amps: 0 to 400A

DC Amps: N/A

0 - 40A = ± 1% of reading

0 - 400A = ± 1.5% of reading

1mA per 1A

Maximum Conductor Size: 1.34” (34mm)

Lead Length: 48” (1.2m)

Output Connection Type: Dual banana plug

Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC (2V AC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

A254 (AC/DC Amp Low Current Probe Adapter)

AC Amps: 10mA to 40A

DC Amps: 10mA to 60A

± (1.5% +20mA)
basic accuracy

10mV per 1A or 100mV per 1A

Maximum Conductor Size: 0.35” (9mm)

Lead Length: 48” (1.2m)

Output Connection Type: BNC connector with removable banana plug adapter

Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

A256 (AC/DC Amp Current Probe Adapter)

AC Amps: 0 to 400A

DC Amps: 0 to 400A

0 - 400A = ± 1% of reading

0 - 2000A = ± 1.5% of reading

1mV per 1A

Maximum Conductor Size: 1.34” (34mm)

Lead Length: 48” (1.2m)

Output Connection Type: Dual banana plug

Most TPI brand and any competitor DMM, clamp-on or oscilloscope having
the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M
Ohm input impedance, and equipped with industry standard spaced input
jacks 19mm on center.
Copyrig

A296 (AC/DC Amp Current Probe Adapter)

AC Amps: 0 to 1600A

DC Amps: 0 to 2000A

0 - 400A = ± 1% of reading

0 - 2000A = ± 1.5% of reading

1mV per 1A

Maximum Conductor Size: 1.34” (34mm)

Lead Length: 48” (1.2m)

Output Connection Type: Dual banana plug

Most TPI brand and any competitor DMM, clamp-on or oscilloscope having
the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M
Ohm input impedance, and equipped with industry standard spaced input
jacks 19mm on center.

  

  

  

Pressure Adapters
Turn a tester into a manometer with TPI pressure adapters.

 

Model # 
Description

Image

Range

Accuracy

Output

General Specifications

Compatible Units

A620 (Pressure Adapter)

 

 


Data Sheet

1 to 500 psi

1 to 30 inHg

± (1% of reading, + 0.3 psi)

± (1% of reading, + 0.5 inHg)

1mVDC per 1 psi

1mVDC per 1 inHg

Input Connection: 1/4” NPT

Lead Length: 78” (2m)

Output Connection Type: Dual banana plug

Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

 

A630 (Pressure Adapter)

 

 


Data Sheet

10 to 10,00 psi

1 to 700 Bar

± (1% of reading, + 10 psi)
± (1% of reading, + 0.5 Bar)

1mVDC per 10 psi

1mVDC per 1 Bar

Input Connection: 1/4” NPT

Lead Length: 78” (2m)

Output Connection Type: Dual banana plug

Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

 

 

 

Temperature Adapters
Adds temperature measurement to a tester.

  

  • Model # 
    Description

    Image

    Range

    Accuracy

    Output

    General Specifications

    Compatible Units

    A301 (Single Input K-Type Temperature Adapter)

     

     


    Data Sheet

    -40° F to 500° F

    +/- (0.75% of full scale + 1° F)

    1mVDC per 1° F

    Input: Single w/ Sub-mini Connector

    Thermocouple: K-Type

    Output Connection Type: Dual banana plug

    Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M> Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

     

    A312 (Dual Input K-Type Temperature Adapter)

     

     


    Data Sheet

    -50 F to 1800 F

    -50 C to 1000 C

    +/- (0.5% of rdg + 3.6 F)

    +/-(0.5% of rdg + 2.0 C)

    1mVDC per 1 F

    1mVDC per 1 C

    Input: Dual w/ Sub-mini Connector

    Thermocouple: K-Type

    Output Connection Type: Dual banana plug

    Additional: Displays difference between T1 and T2

    Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M> Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

     


      
  • Carbon Monoxide Adapters
    The TPI A771 measures CO levels in ambient air. Click here to learn more
 
   
 

 
 

©1997 - 2012 Test Products International, Inc. All Rights Reserved./td> Legal Notice Contact TPI About TPI Site Map