skip to Main Content

TPI adapters add functionality to digital multimeters, clamp-ons, handheld oscilloscopes. Many adapters willl work with competitors’ equipment. All of the Adapters on this page are RoHS Compliant.

AC Amp Current Probe Adapter.

Click for Data Sheet
 A250 Specifications
 Range  AC Amps: 0 to 400A
 DC Amps: N/A
 Accuracy   0 - 40A = ± 1% of reading
 0 - 400A = ± 1.5% of reading
 Output  1mA per 1A
 Maximum Conductor Size  1.34” (34mm)
 Lead Length  48” (1.2m)
 Output Connection Type  Dual banana plug

Compatible Units: TPI 153, 163, 183, 183A, and 440 to obtain .01 A resolution.

Current Adapters
Enables DMMs and other testers to measure electrical current.

 

AC Amp Current Probe Adapter.

Click for Data Sheet
Click for Data Sheet

Where to Buy TPI Products

 A251 Specifications
 Range  AC Amps: 0 to 400A
 DC Amps: N/A
 Accuracy  0 - 40A = ± 1% of reading
 0 - 400A = ± 1.5% of reading
 Output  1mA per 1A
 Maximum Conductor Size  1.34” (34mm)
 Lead Length  48” (1.2m)
 Output Connection Type  Dual banana plug

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC (2V AC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

AC/DC Amp Low Current Probe Adapter.

Click for Data Sheet
Click for Data Sheet

Where to Buy TPI Products

 A254 Specifications
 Range  AC Amps: 10mA to 40A
 DC Amps: 10mA to 60A
 Accuracy  ± (1.5% +20mA) basic accuracy
 Output  10mV per 1A or 100mV per 1A
 Maximum Conductor Size  0.35” (9mm)
 Lead Length  48” (1.2m)
 Output Connection Type  BNC connector with removable banana plug adapter

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

AC/DC Amp Current Probe Adapter.

Click for Data Sheet
Click for Data Sheet

Where to Buy TPI Products

 A256 Specifications
 Range  AC Amps: 0 to 400A
 DC Amps: 0 to 400A
 Accuracy  0 - 400A = ± 1% of reading
 0 - 2000A = ± 1.5% of reading
 Output  1mV per 1A
 Maximum Conductor Size  1.34” (34mm)
 Lead Length  48” (1.2m)
 Output Connection Type  Dual banana plug

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

AC/DC Amp Current Probe Adapter.

Click for Data Sheet
Click for Data Sheet

Where to Buy TPI Products

 A296 Specifications
 Range  AC Amps: 0 to 1600A
 DC Amps: 0 to 2000A
 Accuracy  0 - 400A = ± 1% of reading
 0 - 2000A = ± 1.5% of reading
 Output  1mV per 1A
 Maximum Conductor Size  1.34” (34mm)
 Lead Length  48” (1.2m)
 Output Connection Type  Dual banana plug

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

 

Temperature Adapters
Adds temperature measurement to a tester.

Single Input K-Type Temperature Adapter.

Click for Data Sheet

Where to Buy TPI Products

 A301 Specifications
 Range  -40° F to 500° F
 Accuracy  +/- (0.75% of full scale + 1° F)
 Output  1mVDC per 1° F
 Input  Single w/ Sub-mini Connector
 Thermocouple:  K-Type
 Output Connection Type  Dual banana plug

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M> Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

Dual Input K-Type Temperature Adapter.

Click for Data Sheet
Click for Data Sheet

Where to Buy TPI Products

 A312 Specifications
 Range  -50 F to 1800 F
 -50 C to 1000 C
 Accuracy  +/- (0.5% of rdg + 3.6 F)
 +/-(0.5% of rdg + 2.0 C)
 Output  1mVDC per 1 F
 1mVDC per 1 C
 Input  Dual w/ Sub-mini Connector Thermocouple: K-Type
 Thermocouple:  K-Type
 Output Connection Type  Dual banana plug
 Additional  Displays difference between T1 and T2

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M> Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

 

Pressure Adapters
Turn a tester into a manometer with TPI pressure adapters.

Pressure Adapter.

Click for Data Sheet
Click for Data Sheet

Where to Buy TPI Products

 A620 Specifications
 Range  1 to 500 psi
 1 to 30 inHg
 Accuracy  ± (1% of reading, + 0.3 psi)
 ± (1% of reading, + 0.5 inHg)
 Output  1mVDC per 1 psi
 1mVDC per 1 inHg
 Input Connection  1/4” NPT
 Lead Length  78” (2m)
 Output Connection Type  Dual banana plug

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.

Pressure Adapter.

Click for Data Sheet
Click for Data Sheet

Where to Buy TPI Products

 A630 Specifications
 Range  10 to 10,00 psi
 1 to 700 Bar
 Accuracy  ± (1% of reading, + 10 psi)
 ± (1% of reading, + 0.5 Bar)
 Output  1mVDC per 10 psi
 1mVDC per 1 Bar
 Input Connection  1/4” NPT
 Lead Length  78” (2m)
 Output Connection Type  Dual banana plug

Compatible Units: Most TPI brand and any competitor DMM, clamp-on or oscilloscope having the capability of measuring up to 2000mV AC/DC (2V AC/DC), 10M Ohm input impedance, and equipped with industry standard spaced input jacks 19mm on center.
Back To Top