True RMS DMM with temperature, capacitance, duty cycle, and low-pass filter.
- 4,000 count display
- True RMS for more accurate measurements
- Auto/manual ranging
- Temperature measurement
- Duty cycle to measure the amount of time the motor is on
- Low pass filter for noisy environments
- Separate fuse (2) and battery compartment
- IR serial interface
- cULus 61010-1
- CAT II – 1000V, CAT III – 600V
$159.95 USA Suggested List Price
The 183A is a hand-held autoranging DMM. The 183A measures ACV, DCV, ACA, DCA, Resistance, Frequency, Duty Cycle, Diodes, Capacitance, Temperature and Continuity. The meter is also easy to use and built to last. The DMM 183A also features:
- REC: Records Min/Max readings during specified measurement intervals.
- RANGE: Allows the user to manually range the 183A instead of autoranging.
- Data Hold: Holds the reading on the display for easy viewing.
- REL: Displays the value as a difference to a reference value.
- Auto Off: Preserves battery life.
Additional Features and Benefits of the Model 183A:
- Duty cycle (% pulse width modulation) for measuring modulating gas valves
- Low pass filter for noisy environments
- Separate fuse (2) and battery compartment
- IR serial interface that can be used to input data to PC with optional A183
- High resolution (0.01) low DC microamp range for measuring flame safety control circuit
- Frequency, capacitance, temperature, data hold, min/max record, relative mode
- AC/DC volts, AC/DC amps, resistance, audible continuity and diode test
The 183A comes complete with the following accessories:
- 183A Instrument
- Rubber Boot
- Thermocouple probe and adapter
- Test Lead Set
- Instruction Manual
Category Ratings:
- Category I: Usually electronic equipment or equipment where measures have been taken to limit transient over voltages.
- Category II: Single phase loads like appliance personal computers, television sets, and other household loads. Outlets located more than 30 feet froma CAT III source or more than 60 feet from a CAT IV source.
- Category III: Distribution level fixed installations like distribution panel devices, short branch and feeder circuits, three phase loads, and single phase commercial lighting.
- Category IV: Equipment and lines located on the power line side of a service panel or where a low voltage connection is made to utility power
Model 183A Specifications | ||
---|---|---|
DC Volts | Maximum Input: 1000V
Maximum Resolution: 0.01mV Basic Accuracy: +/-0.5% |
|
AC Volts | Maximum Input: 750V
Maximum Resolution: 0.01mV Basic Accuracy: +/-1.5% |
|
DC Amps | Maximum Input: 10A
Maximum Resolution: 0.01μA Basic Accuracy: +/-0.8% |
|
AC Amps | Maximum Input: 10A
Maximum Resolution: 0.01μA Basic Accuracy: +/-1.2% |
|
Resistance (Ohms) | Maximum Input: 40MΩ
Maximum Resolution: 0.1mΩ Accuracy: +/-0.05% |
|
Frequency | Maximum Input: 10MHz
Maximum Resolution: 0.01Hz Accuracy: +/-0.05% |
|
Capacitance | Maximum Input: 4000µF
Maximum Resolution: 0.01nF Accuracy: +/-3% |
|
Temperature
(K-Type Thermocouple) |
Maximum Input: 2372°F (1300°C)
Maximum Resolution: 0.1°F / °C Accuracy: +/-2% |
|
Continuity | Audible at less than 30Ω | |
Diode | 2.7V at 1mA maximum output | |
Duty Cycle | Range: 0.1 to 99.9%
Accuracy: Accuracy: +/-(0.1% + 0.05% /KHz) + 1 count |
|
True RMS Responding | Yes | |
Conductance | No | |
Pulse Width | No | |
Data Hold | Yes | |
Min/Max Record | Yes | |
Time Stamp Logging | No | |
Relative Mode | Yes | |
Protective Boot | Yes (standard) | |
Display Type | 4000 count LCD, 2 times per second update | |
Range Selection | Auto/Manual | |
Operating Temperature | 0° to 40°C (32° to 104°F) | |
Storage Temperature | -10° to 50°C (14° to 122°F) | |
Relative Humidity | 0% to 80% | |
Size | 33mm x 86mm x 187mm (1.3in x 3.4in x 7.4in) | |
Weight | 12oz (340g) with boot | |
Battery Type | 9V Alkaline | |
Battery Life | 200hrs Typical | |
OverInput Category | CAT III 600V | |
Agency Approval | cULus 61010-1, IEC 61010-1 | |
Warranty | 3 Years |
Model 183A Applications
- Test run and start capacitors
- Measure ambient and duct temp
- Test control (thermostat, thermocouple, flame safety) and line voltages
- Measure resistance and test for continuity
- Line current up to 10amps (in series)
Frequently Asked Questions
1. Is there a way to measure higher current with a TPI DMM?
TPI DMMs (except the 120 and 126) have the capacity to read up to 10A AC/DC. Optional adapters are available for all models to increase the current range. Our shunt adapters are available to increase the range up to 1,000A AC/DC.
2. What other adapters are available for TPI DMMs?
Various adapters including carbon monoxide (A771), pressure (A620/630), and clamp-on low current (A254) are available. Contact TPI for additional information.
3. Which of the TPI DMMs will measure temperature?
All TPI DMMs can measure temperature by using the optional A301 K-Type thermocouple temperature adapter, excluding the 183A which requires the A106 adapter along with any K-Type thermocouple probe. The 183A comes standard with the A106 adapter and GK-11M probe.
4. Which TPI DMMs can measure DC millivolts?
All TPI DMMs measure millivolts. Models are available with 1 or 0.1 millivolt resolution.
5. Which TPI DMMs can measure DC microamps?
The TPI 126, 133, 135, 153, 163, 183, 190, 194, 196, and 440 all have this capability.
6. Which TPI DMMs will measure capacitance?
The TPI 135, 183, 190, 192, 194, and 440 all have this capability.
7. What is continuity?
Continuity refers to a test performed on wires and circuits to see if a break(open) exhists. If the wire or circuit is continuous, the resistance reading will be at or near zero. The continuity range on a meter provides audible indication of a continuous circuit, allowing quicker tests without having to take your eyes off the circuit or wire under test.