The combo CO/Combustible gas detector is the first of its kind to combine both detection technologies into one easy to use hand-held and affordable instrument.

775 Carbon Monoxide and Combustible Gas Leak Detector

The TPI 775 is a state-of-the-art Carbon Monoxide and Combustible Gas Leak Detector. It is the first of its kind to combine both detection technologies into one easy to use hand-held affordable instrument.

  • One hand operation
  • Auto Zero
  • Backlight
  • Visable and audible alarm

$374.95
USA Suggested List Price

Tequipment.net
Grainger
Digi-Key Electronics

Standard Accessories
• Instruction Manual
• Soft Pouch

Optional Accessories
• Earphones

Don’t expose yourself to Carbon Monoxide!

Review the list below for the maximum allowable exposure limits and symptoms developed with CO inhalation.

  • 9ppm: The maximum allowable concentration for short term exposure in a living area according to ASHRAE
  • 50ppm: The Federal OSHA standard for continuous exposure in any eight hour period.
  • 200ppm*: Maximum concentration allowable any time according to OSHA. Slight headaches, fatigue, dizziness, nausea after 2-3 hours.
  • 400ppm*: Frontal headaches within 1-2 hours, life threatening after 3 hours. Maximum allowable limit in flue gas according to EPA and AGA.
  • 800ppm*: Headache, dizziness, nausea, and convulsions with 45 minutes. Unconsciousness within 2 hours. Death within 2-3 minutes.
  • 1600ppm*: Headache, dizziness, and nausea within 20 minutes. Death within 1 hour.
  • 3200ppm*: Headache, dizziness, and nausea within 5-10 minutes. Death within 30 minutes.
  • 6400ppm*: Headache, dizziness, and nausea within 1-2 minutes. Death within 10-15 minutes.
  • 12800ppm*: Death within 1-3 minutes.

* With exposure to this concentration and higher the effects can vary depending on size, age, sex, and health.

 Model 775 Specifications
 Carbon Monoxide (CO) Measurement  Range 0 ~ 2,000ppm
 Accuracy  ±5ppm or 5% of reading whichever is greater
 Resolution  1ppm
 Data Storage  No
 IR Printer Port  No
 Flue Probe  No
 Internal Pump  No
 Combustible Gas Leak Detection  Yes
 Backlight  Yes
 Alarm  Audible + Visual
 Power Supply  1.5V AA (2)
 Dimensions  9.5” x 2.9” x 2.2” (240 x 74 x 55 mm)
 Weight  1.05lbs (476g)
 Warranty  3-year limited warranty 2-year sensor warranty

TPI Model 775 Demonstration Video

Model 775 Applications

  • CO safety measurements in and around combustion sources
  • Ambient CO safety checks
  • Combustible Gas Detection

Frequently Asked Questions

Why should I purchase a pump driven CO analyzer rather than a less expensive CO monitor?
A pump driven analyzer is a much more versatile tool. The pump draws a sample into the instrument which allows source pinpointing. A pump driven instrumentwill also respond faster, and can be used for hot air (flue) sampling.

Can a CO analyzer be used for heat exchanger testing?
While a CO analyzer can provide a safety test of the furnace, it cannot provide a discernable test for heat exchanger integrity. The TPI HXG2 and HETKIT are recommended for this test and together are AGA approved.

How often should I calibrate my CO analyzer?
It depends on the use of the instrument. If used for service work, it is recommended that an annual calibration be performed. If any aspect of worker safety is included in the instrument’s job, monthly calibration is recommended.

If I perform my own calibration, do I increase my liability?
As long as traceable calibration gas is used and manufacturer’s calibration procedures are followed, liability will be minimized. Calibration records should be documented and retained.

How many calibrations can I expect out of a 21 liter bottle of calibration gas?
35-50 calibrations

How long will the CO sensor last?
Two to three years.